Caution, Caution warning caution – Yaskawa Σ-II Series User Manual
Page 9

E-5
INSTALLATION
WIRING
(Ref.No.)
• There is a limitation in the combination of the software version of the SGDH SER-
VOPACK and the software version of the NS100 Module.
When the software version of the SGDH SERVOPACK is 11 or lower: Applicable to
all the versions of the NS100
When the software version of the SGDH SERVOPACK is 12 or higher: Applicable
to version 7 or higher of the NS100
When the wrong combination is used, an alarm A.BF SYSTEM ERROR (operation error)
may occur.
E-9
• When SGDH SERVOPACK is used with a NS100 Module mounted, the parame-
ters are automatically set so that the NS100 Module can be operated from the first
power ON.
For details of parameter setting methods, refer to
Σ-II Series SGM /SGDH User’s Manual
Desine and Maintenance (SIE-S800-32.2).
E-10
(Ref.No.)
• Never use the equipment where it may be exposed to splashes of water, corrosive
or flammable gases, or near flammable materials.
Failure to observe this caution may result in electric shock or fire.
E-14
(Ref.No.)
• SERVOPACK grounding must be in accordance with the national code and consis-
tent with sound local practices.
Failure to observe this warning may result in electric shock or fire.
E-17
(Ref.No.)
• Do not connect three-phase power supply to SERVOPACK output terminals U, V,
and W.
Failure to observe this caution may lead to personal injury or fire.
E-17
• Securely tighten screws on the power supply and motor output terminals.
Failure to observe this caution may result in a fire.
E-17
CAUTION
CAUTION
WARNING
CAUTION