2 precautions on wiring – Yaskawa Σ-II Series User Manual
Page 23

4 WIRING
E-19
4.2 Precautions on Wiring
Take note the following precautions at wiring.
Connectable Maximum Number of Stations
Up to 15 slave stations can be connected.
Cables
Use the following cables.
For other peripheral devices, refer to
Σ-II series SGM H/SGDH User’s Manual Design
and Maintenance (SIE-S800-32.2) and
Σ-II series SGDH MECHATROLINK Interface
Module User’s Manual (SIE-C718-4).
Total cable length
The total cable length should be 50 m and less.
(Station 1 + Station 2 + ••• Station
≤ 50 m)
Terminator
Be sure to install the following terminator on SERVOPACK of terminal station.
Cable
Type
Length (m)
MECHATROLINK Communication Cable
(With connector on both ends)
JEPMC-W6000-A3
0.3
JEPMC-W6000-A5
0.5
JEPMC-W6000-01
1.0
Terminator
Type
MECHATROLINK Communication Terminator
JEPMC-W6020