5 wiring examples – Yaskawa Σ-II Series User Manual
Page 29

7 MEASURES TO SATISFY THE EMC DIRECTIVE
E-25
7.5 Wiring Examples
The following diagrams show the wiring example. Before wiring, turn OFF the Power ON/
OFF switch and post a notice of “No Conduction”. Only an electrical expert can perform the
wiring. The noise filter and the core are shown in the diagram.
Note: 1. Clamp: Secure cable shields and ground for conductive metal parts.
2. Make sure that the grounding plate are securely connected to the grounding.
3. Remove the paint from the grounding plate to insure a good Earth connection for filter,
SERVOPACK, clamp, etc.
Grounding plate/Box
Three-phase
400 V
Signal-phase
200 VAC
Clamp
Noise
filter 1
Noise
filter 2
AC/DC
converter
CN1
Core
Core
Core
Core
Core
Core
Core
Open
Moter
Servomotor
Host controller
Encoder
Core
Core
Clamp
Clamp
Clamp
Clamp
Core
Control box
I/F module
JUSP-NS100
SGDH
SERVOPACK
L1, L2, L3
A1, A2
CN6A
CN6B
U, V, W,
CN2
Clamp
Main
power
supply
Control
power
supply