Caution warning caution – Yaskawa Σ-II Series User Manual
Page 10

E-6
OPERATION
INSPECTION AND MAINTENANCE
(Ref.No.)
• To avoid inadvertent accidents, run the servomotor only in test run (without load).
Failure to observe this caution may result in personal injury.
E-20
• Before starting operation with a load connected, set up parameters suitable for the
machine.
Starting operation without setting up parameters may result in machine overrun or failure.
E-20
• Before starting operation with a load connected, make sure emergency-stop proce-
dures are in place.
Failure to observe this caution may result in personal injury.
E-20
• During operation, do not touch the SERVOPACK’S heatsink.
Failure to observe this caution may result in burns.
E-21
(Ref.No.)
• Never touch the inside of the SERVOPACKs.
Failure to observe this warning may result in electric shock.
E-22
• Never open the terminal cover while power is ON, and never turn ON power when
the terminal cover is open.
Failure to observe this warning may result in electric shock.
E-22
• After turning OFF power, wait at least five minutes before servicing the product.
Otherwise, residual electric charges may result in electric shock.
E-22
(Ref.No.)
• Never change wiring while power is ON.
Failure to observe this caution may result in electric shock or personal injury.
E-22
CAUTION
WARNING
CAUTION