16 Ethernet Connector Details

YASKAWA America, Inc. MP3300iec Hardware Manual YAI-SIA-IEC-7

29

Note: Recommended ferrite core.

CAUTION

High frequency wave noise from other devices in the installation environment may cause errors in
communications using Ethernet or MECHATROLINK-III connections. When designing a system, use protective
measures to avoid the influence of high frequency wave noise as follows:

1. Wiring

Wire Ethernet or MECHATROLINK-III cables so that they are well-separated from other cable systems such as the main circuit or
power lines.

2. Communication system (Ethernet)

Communicate data to a remote device through TCP/IP communication.
If necessary, increase the number of communication retries.
Yaskawa strongly recommends shielded Ethernet cables.

3. Attach a ferrite core.

Ethernet: Attach it to the communication port side and the external equipment side of the MP3300iec unit.

Model

Manufacturer

E04SR301334

Seiwa Electric Mfg. Co., Ltd

Hub

or Switch

MotionWorks IEC

MP3300iec

YASKAWA SERVOPACK

200V

SGDS-01A12A

SW1

CHARGE

C
N
3

A/B

C
N
1

C
N
2

C
N
4

L1

L2

L2C

L1C

B1/

B2

U

V

W

C
N
6

SERVOPACK

Core

Core

Core

100Base-T

(straight cable)

Servomotor

Other station