YASKAWA America, Inc. MP3300iec Hardware Manual YAI-SIA-IEC-7

5 CPU Specifications

5

CPU Specifications

The hardware specifications of the CPU Unit are given in the following table.

‹

CPU Communications Specifications

The specifications of the Communications Protocols built into the CPU Module are given in the following table.

Item

CPU Specification

Model

PMC-U-MP330xx

Part Number: Description

PMC-U-MP33004: CPU, MP3300, 4 axis, 400 MHz, 4MB SRAM
PMC-U-MP33008: CPU, MP3300, 8axis, 400 MHz, 4MB SRAM
PMC-U-MP33020: CPU, MP3300, 20 axis, 400 MHz, 4MB SRAM
PMC-U-MP33320: CPU, MP3300, 20 axis, 800 MHz, 8MB SRAM
PMC-U-MP33332: CPU, MP3300, 32 axis, 800 MHz, 8MB SRAM

Flash Memory

Capacity: 40 MB (32 MB of user memory)

SDRAM

Capacity: 128 MB

SRAM

Capacity: 8 MB (battery backup)

Calendar

Seconds, minutes, hour, day, week, month, year, day of week, and timing (battery backup)

Ethernet

10Base-T or 100Base-TX

MECHATROLINK

MECHATROLINK-III: 1 circuit with 2 ports

USB

USB 2.0 Type A host, 1 port
Compatible devices: USB storage

Indicators and Displays

Seven-segment display
Status indicators
USB status indicator
MECHATROLINK-III status indicators
Ethernet status indicators

Switches

DIP switch: Mode switch
STOP/SAVE switch.

Refer to Switches on page 16

for detailed switch information.

Protocol

Mode

Detail

Modbus TCP

MP3300iec as Master (Client)

Maximum Number of Data Blocks = 20

MP3300iec as Slave (Server)

1000 registers in, 1000 registers out, 256 coils in, 256 coils out

Ethernet/IP

MP3300iec as Master (Scanner)

Maximum Number of Data Blocks = 100

MP3300iec as Slave (Adapter)

Total of 16 instances in, 16 instances out, arranged as 3 instances of

256 bytes, 3 instances of 128 bytes, and 10 instances of 496 bytes.

OPC

read/write

Any Global variable can be configured, requires OPC Server running

on PC

Custom Protocol

n/a

Use the YDeviceComm firmware library to create a custom

communication protocol.

Network Variables

read/write

Variables configured with MotionWorks IEC software that allow

automatic data transfer from controller to controller.