Page 49

SB 1300TL-10
SB 1600TL-10
SB 2100TL
Total harmonic distortion of the output
current with total harmonic distortion
of the AC voltage < 2%, and AC
power > 50% of the rated power
≤3%
≤3%
≤3%
Rated power frequency
50 Hz
50 Hz
50 Hz
AC power frequency
50 Hz / 60 Hz
50 Hz / 60 Hz
50 Hz / 60 Hz
Operating range at AC power fre-
quency 50 Hz
44 Hz to 55 Hz
44 Hz to 55 Hz
44 Hz to 55 Hz
Operating range at AC power fre-
quency 60 Hz
54 Hz to 65 Hz
54 Hz to 65 Hz
54 Hz to 65 Hz
Power factor at rated power
1
1
1
Feed-in phases
1
1
1
Connection phases
1
1
1
Overvoltage category in accordance
with IEC 60664-1
III
III
III
Efficiency
SB 1300TL-10
SB 1600TL-10
SB 2100TL
Maximum efficiency, η
max
96.0%
96.0%
96.0%
European efficiency, η
EU
94.3%
95.0%
95.2%
General Data
Width x height x depth
440 mm x 299 mm x 214 mm
Width x height x depth, with ESS
440 mm x 339 mm x 214 mm
Weight
16 kg
Length x width x height of the packaging
532 mm x 392 mm x 318 mm
Weight including packaging
21.5 kg
Climatic category in accordance with
IEC 60721-3-4
4K4H
Operating temperature range
-25°C to +60°C
Maximum permissible value for relative humid-
ity, non-condensing
100%
Maximum operating altitude above mean sea
level (MSL)
2,000 m
Noise emission, typical
≤33 dB(A)
11 Technical Data
SMA Solar Technology AG
Operating Manual
49
SB13-21TL-BE-en-11