User Manual

9 Troubleshooting

#

Problem

Cause

Rectification

1 The network is not

available.
(Error code: 12028)

Incorrect network
configuration

• Check the network settings for the

installed network components
(e.g., server, router, Sunny WebBox
devices, etc.) and adjust if necessary.

Defective network
component cabling and
plug connections

• Check cabling and plug connections of

the individual network components
(e.g., server, router, Sunny WebBox
devices, etc.) for damage, and replace
damaged cables or plugs, if necessary.

Defective network
components

• Check that the individual network

components (e.g., server, router, Sunny
WebBox devices, etc.) are operating
properly. Replace defective devices if
necessary.

Incorrect internet access
data

• Check internet access data. Correct

settings if necessary.

2 The namespace file

cannot be saved.

Missing write
permission on the drive

• You require write permission for the drive

on which the SMA OPC Server is
installed. Change your user rights and
re-detect the namespace.

3 The config file cannot

be saved.

Missing write
permission on the drive

• You require write permission for the drive

on which the SMA OPC Server is
installed. Change your user rights.

4 The namespace file

could not be
imported.

Invalid namespace file
format

• Only namespace files that were exported

via the SMA OPC Server configuration
interface can be imported.

• The namespace file must not be changed.

5 The program is

already running.

The SMA OPC Server
can only be started
once.

• Exit the SMA OPC Server before

restarting the server.