4.2.1 Commissioning a Speedwire System
1. Commission the Speedwire inverters and connect to the network as described in the respective
manual.
☑ The Speedwire system is commissioned and the Speedwire inverters are connected to the
network.
2. Establish a connection to your Speedwire system using Sunny Explorer (see Section 4.2.2,
4.2.2 Creating a New Speedwire System
Requirement:
☐ The Speedwire system must be commissioned (see Section 4.2.1, page 16).
Procedure:
1. Start Sunny Explorer.
☑ The system assistant opens.
2. Select Enter a new system in the system assistant.
3. Enter the desired name for the system in the field System name. This name can be freely
selected and will be used as the file name for the system file.
4. To configure a different directory for saving the system file, click on the button [...] in the field
Directory.
5. Select [Next].
6. In the drop-down list Communication type, select the entry Speedwire and then [Next].
☑ The system search begins.
☑ Sunny Explorer searches for Speedwire devices in all network connections linked to the
computer.
☑ If there are multiple network connections to Speedwire devices, these are listed in a tree
view and the devices found are displayed as sub-nodes.
7. If multiple network connections are displayed, select the network connection to which the
Speedwire devices are connected and select [Next].
☑ The connection to the selected Speedwire network is established and the login window
opens.
8. Select the user group in the drop-down list User group. The user group Installer must only be
used by qualified personnel who are familiar with setting safety-relevant system parameters.