Operating instructions – Enviro Meridian C-10135 User Manual
Page 9
PRE-BURN INSTRUCTIONS
: The burn pot liner holes must be clear and the liner installed properly against
the ignitor tube for proper operation. Check the hopper for enough pellets to start the unit.
DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN AJAR
MANUAL MODE:
To START:
Press the ON / OFF Button. The stove will turn on. The System Light will flash. The Auger Light will flash with
each pulse of the auger (the Auger Feed Rate is pre-programmed during start-up). The Heat Level Indicator will
show the Heat Level that the stove will run at after start-up.
If this is the first time the unit has been started or the unit has run out of fuel, the auger will need to be primed.
Press the Manual Auger Feed button until fuel starts to drop into the Burn Pot Liner.
To OPERATE:
When a fire has been established, the System Light will turn solid, the Auger Light will continue to flash to the
corresponding Heat Level setting. The Heat Level button can now be pressed to change the desired Heat Level
Output setting.
The convection blower (room air blower) will turn on. The speed of this blower is controlled by the setting of the
heat level output indicator. The convection blower can be turned OFF by depressing the convection blower control
button. When the air jacket reaches 160° F (71° C) the convection blower will come ON High, cooling the unit. For
the best efficiency and to prevent cycling, the convection blower should be left on at all times.
When operating on LOW HEAT LEVEL, the feed rate can be adjusted for different quality fuels. These settings can
be used if the fire keeps going out on low (poor quality fuel). Or if the low setting is too hot for the room (see
STOVE CONTROLS).
THERMOSTAT / SWITCH MODE:
INITIAL START-UP: See above
OPERATION - HI / LOW mode: When the thermostat contacts are closed the stove settings are adjustable
as per Manual Mode (see above). When the thermostat contacts open, the circuit board will take control of the
settings. The stove will drop down to a low burn until the thermostat contacts close again. This low burn setting
can be adjusted for different fuel qualities (see STOVE CONTROLS). The stove will come back to the previous
HEAT LEVEL setting when the thermostat contacts close again.
OPERATION – ON / OFF mode: When the thermostat contacts close, the unit will light automatically. Once
up to temperature, the stove operates the same as in manual mode (see above). When the thermostat contacts
open, the unit automatically begins its shutdown routine. The stove will re-light when the thermostat contacts
close again.
•MANUAL and HI / LOW mode: To turn the unit OFF, simply press the ON / OFF button. This will stop the feed of
pellets. The blowers will continue to operate and cool the stove down. When cool enough, the stove will turn off.
•ON / OFF mode: To turn the unit OFF, turn the thermostat down or off.
DO NOT unplug unit while Combustion fan is operating.
This may lead to smoke escaping from the stove.
T
URNING
Y
OUR
P
ELLET
S
TOVE
O
FF
:
O
PERATING
Y
OUR
P
ELLET
S
TOVE
:
Operating Instructions
9