beautypg.com

Installation – Enviro Meridian C-10135 User Manual

Page 17

background image

17

The MERIDIAN can be vented through the wall using two different methods. Only use vent of (L or PL) type with

an inside diameter of 3 or 4 inches (7.6 or 10.1 cm)

VENT INSTALLATION: INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.

A chimney connector shall not pass through an attic or roof space, closet or similar concealed spaces, or a floor,

or ceiling. Where passage through a wall, or partition of combustible construction is desired, the installation shall

conform to CAN/CSA-B365, Installation Code for Solid-Fuel-Burning Appliances and Equipment.

STRAIGHT THROUGH THE WALL.

1.

Choose a location for your stove that meets the requirements stated in this manual and allows installation

with the least amount of interference to house framing, plumbing, wiring, etc.

2.

Place the appliance 15” (37.5 cm) away from the wall. If the stove is to be set on a hearth pad, set the unit

on it.

3.

Locate the center of the exhaust pipe on the stove. Extend that line to the wall. Once you have located the

center point on the wall, use a hole saw to cut a 10” (254 mm) diameter hole for a 3” (76 mm) vent pipe or

an 11” (279 mm) hole for a 4” (101 mm) vent pipe.

4.

Install the wall thimble as per the instructions written on the thimble. Maintain an effective vapour barrier

in accordance with local building codes.

5.

Install a length of 3” (76 mm) or 4” (101 mm) vent pipe into the wall thimble. The pipe should install easily

into the thimble.

6.

Install the fresh air intake.

7.

Connect the exhaust vent pipe to the exhaust pipe on the stove. Seal all connections with high temperature

silicone

8.

Push the stove straight back, leaving a minimum of 3” (7.6 cm) clearance from the back of the stove to the

wall. Seal the vent pipe to the thimble with high temperature silicone.

9.

The pipe must extend at least 12” (30 cm) away from the building. If necessary, bring another length of pipe

(PL type) to the outside of the home to connect to the first section. Do not forget to place high temperature

silicone around the pipe that passes through the thimble.

10. Install a vertical pipe, or if all requirements for direct venting are met, install vent termination. The stainless

steel cap termination manufactured by the vent manufacturer is recommended. However, when the vent

terminates several feet above ground level and there are no trees, plants, etc. within several feet, a 45°

elbow with rodent screen can be used as a termination. The elbow must be turned down to prevent rain

from entering.

NOTE:

• Some horizontal through wall installations

may require a “T” and a 3 to 5 foot (91-

152cm) of vertical pipe outside the building

to help natural draft in the unit.

• This may be required if a proper burn

cannot be maintained, after the stove has

been tested and the airflow set.

• This is due to the backpressure in the

exhaust caused by airflow around the

structure.

• All sections of pipe must have three (3)

screws evenly spaced and all horizontal

vent sections must have a bead of high

temperature silicone installed on the male

end of the pipe before installation to create

a gastight seal.

Installation

T

HROUGH

W

ALL

I

NSTALLATION

:

Exhaust Tube

3" (75mm) or 4" (100mm)

"PL" or "L" vent

Wall Thimble

45 deg Elbow

w/screen or

Termination Cap

Fresh Air Intake

High Temperature RTV

Silicone Required