This stove can be placed into two different thermostat modes:

HI / LOW OPERATION:

If the unit has been placed in the HI / LOW mode. The unit will operate on the low setting

when the thermostat is not calling for heat. When the thermostat calls for heat, the unit will go to your selected setting which
is displayed on the control board Heat Output Indicator.

ON / OFF OPERATION:

If the unit has been placed in the ON /OFF thermostat mode, when the thermostat

calls for heat, the unit will go through an ignition sequence and light the stove. Once lit the unit will operate at the

selected setting displayed on the control board Heat Output Indicator. Once the thermostat stops calling for heat,

the unit will stop feeding pellets and begin its’ shut down sequence until cold then turn off.

1. Install the Low Voltage Thermostat (max 24V) in a location that will effectively monitor the desired area to be

heated.

2. Open the right cab side to expose thermostat wires and disconnect. Install 18 gauge (see wiring diagram) or

heavier wire through the grommet in the back, from the stove to the thermostat. Connect thermostat wires to red

wires provided.

3. To set the thermostat jumper to the desired mode, remove the two screws holding the circuit board control panel

in place. Lower the board and pull out to change jumper.

A) HI / LOW: when the jumper

is placed on only one of the J9

pins, then the control board is in

a HI / LOW mode of thermostat

operation (factory setting).

B) ON / OFF: If both pins of J9

are jumped (covered) then the

control board is in an ON / OFF

mode of thermostat operation.

T

HERMOSTAT

I

NSTALLATION

:

C) This unit has a convection fan control over-ride. This function causes the convection fan to reach its full speed

when the temperature at the back of the firebox reaches 160° F (71° C). This is a normal safety feature of your

unit.

D) The unit is equipped with a vacuum switch to monitor the venting; if it becomes blocked the vacuum switch will

turn off the auger and the #2 light on the control board will flash.

Operating Instructions