Installation – Enviro Meridian C-10135 User Manual
Page 22
22
Installation
E
XTERIOR
M
OUNTED
E
XHAUST
B
LOWER
:
TO SUPPLY POWER TO THE EXHAUST BLOWER:
Install an amour coated electrical cable from the exhaust blower housing, through the wall thimble, and attach to
the pre-drilled hole in the left hand rear hopper pillar. Hook up to wires from the wiring harness for the exhaust
blower. All electrical connections must be in accordance with local code requirements (SEE WIRING DIAGRAM).
NOTE:
Ensure that all vent connections are installed by placing three screws evenly spaced and a small bead of high
temperature silicone at each chimney connection. Also ensure that all vertical vent sections are properly supported
and that all clearances to combustibles are maintained in accordance with the vent manufacturer’s specifications.
���� ����������� ���
���������� ����� �����������
����� �� �� ������ �����
���� ������ ������
�� ������ �����
���� �����
������������ ����
��� �� ���� �����
�������� ������
��� �������
���� ���� �� � ����
������ �����
���� ������� ���
����� � ���� ������
Wall framing
Wall thimble
Horizontal frame