Installation – Enviro Meridian C-10135 User Manual
Page 14
14
Installation
I
NSERT
C
LEARANCES
TO
C
OMBUSTIBLES
(I
NSTALLED
I
N
M
ASONRY
F
IREPLACE
):
The fireplace insert model includes a surround faceplate and a pedestal. When installing this unit, ensure that the
pedestal is removed from the inside of the hopper and installed on the bottom of the unit.
SIDE WALL
8 inches
(20.3 cm) from the body of the heater
FACING ON MASONRY FIREPLACE
8 inches
(20.3 cm) from the body of the heater
MANTLE
8 inches
(20.3 cm) from the body of the heater
F
REESTANDING
C
LEARANCES
TO
C
OMBUSTIBLES
AND
M
INIMUM
A
LCOVE
S
IZE
:
Maintain these clearances to combustibles.
This unit may be installed in an Alcove.
SIDE WALL TO UNIT 6 inches (20.4 cm)
MIN. ALCOVE WIDTH 36 inches ( 91.4 cm)
BACK WALL TO UNIT 3 inches ( 7.6 cm)
MIN. ALCOVE HEIGHT 48 inches (121.9 cm)
ADJACENT WALL
2 inches ( 5.0 cm)
MIN. ALCOVE DEPTH 30 inches ( 76.2 cm)
���
���
���
��
��
��
I
NSERT
D
IMENSIONS
:
WIDTH:
23 3⁄4 inches (60.4 cm)
HEIGHT:
22 7⁄8 inches (64.6 cm)
DEPTH:
23 7⁄8 inches (60.5 cm)
DEPTH FROM FRONT OF UNIT TO SURROUND:
12 7⁄8 inches (32.6 cm)