9.4 Miscellaneous F

unctions f

o

r Cont

our

ing Beha

vior

Effect

M120 must be located in an NC block that also contains radius
compensation RL or RR. M120 is then effective from this block until

„

radius compensation is canceled with R0, or

„

M120 LA0 is programmed, or

„

M120 is programmed without LA, or

„

another program is called with PGM CALL, or

„

the working plane is tilted with Cycle 19 or the PLANE function.

M120 becomes effective at the start of block.

Restrictions

„

After an external or internal stop, you can only re-enter the contour
with the function RESTORE POS. AT N. Before you start the block
scan, you must cancel M120, otherwise the TNC will output an error
message.

„

When using the path functions RND and CHF, the blocks before and
after RND or CHF must contain only coordinates in the working plane.

„

If you want to approach the contour on a tangential path, you must
use the function APPR LCT. The block with APPR LCT must contain
only coordinates of the working plane.

„

If you want to depart the contour on a tangential path, use the
function DEP LCT. The block with DEP LCT must contain only
coordinates of the working plane.

„

Before using the functions listed below, you have to cancel M120
and the radius compensation:

„

Cycle 32 Tolerance

„

Cycle 19 Working plane

„

PLANE function

„

M114

„

M128