BCD Data Interface (X33)
There are several ways to start measured value output:
ä Press MOD repeatedly until the PRINT indicator blinks
(only for“slow” data output), then start data output with
ENT;
or
ä Let the measured values periodically be sent to the data
output;
or
ä nput a latch command at the D-sub connection EXT;
or
ä nput a latch command at the BCD connection.
Interface Operating Mode (see Operating Parameter P53)
slow–
Display value
fast –
Display value referenced to datum 1
(MIN/MAX/DIFF display values are not shown)
You can order a connecting cable (to a PC, for example) from
HEIDENHAIN (Id. Nr. 206 420-..); maximum cable length 10 m.
Operating parameters for display output: P23, P53 to P57,
P84.
BCD Data Interface (X33)
“AMP-Champ“ Connector (36-pin, female)
Pins
Assignment
2
0
2
1
2
2
2
3
1
2
3
4
Decade 1
5
6
7
8
Decade 2
9
10
11
12
Decade 3
13
14
15
16
Decade 4
17
18
19
20
Decade 5
21
22
23
24
Decade 6
25
26
27
28
Decade 7
29
30
31
32
Decade 8
Pins
Assignment
33
Algebraic sign
34
Ready message
35
Display value
36
0V
Output Level
Low: U £ 0,4 V at I £ 6 mA
High: U ³ 3,8 V at I £ 2,6 mA
The output signals are TTL
compatible.
Latch level
Low: U £ 0,9 V at Imax £ 6 mA
High: U ³ 3,9 V; or
TTL level (internald pull-up
resistor 10 k
W).