Configuration

Power Alarm

The power alarm can be switched with switch

SW 7

according to the pattern

given in

Table 28

. The default setting is power alarm disabled.

Power-up Mode

Switch

SW 8

on the configuration switch defines the power up mode on

NxN square routers, and enables input extension on 16x2 routers. The
Triton Plus router provides two modes for powering up the system.

The power up options can be switched according to the following pattern
given in

Table 29

:

Default setting switches all outputs according to the buffered information
in the routers processor system.

Configuring Output on Single Bus Panels

Refer to

Input on page 30

for configuring default output to be controlled

from a single bus control panel.

Table 28. SW 7 – Power Alarm

SW 7

Power Alarm

Off

Disables power alarm

On

Enables power alarm

Table 29. SW 8 – Power Up Mode

SW 8

Power Up Mode

Off

Switches all outputs according to the buffered information in
the routers processor system.

On

Switches all outputs to input 1.