beautypg.com

Switcher polling address, Serial communications protocol selection, Table 24. protocols and applications – Grass Valley Performer-HD User Manual

Page 26

background image

2-8

Performer-HD Instruction Manual

Section 2 — Installation

Switcher Polling Address

Performer will accept a polling address from 0 to 255. A polling address is
necessary if more than one switcher is being controlled by a single control-
ler. The full address range is not available to all protocols. Refer to the list
below for protocol address ranges:

Performer ASCII

Full Range

GVG Model 100 or 110

Full Range

SMPTE 3245-E

40-255 (28H-FFH)

Serial Communications Protocol Selection

Performer is designed to allow serial control from multiple sources. Several
communications protocols are serviced; RS232, ASCII and SMPTE are
available by setting the proper switches. Protocols and their applications
are listed in

Table 2-4

.

To set up a protocol, select protocol, message parity, bit rate, and switcher
polling address. For ASCII protocols, also set serial port data bits at 7 or 8.
For other protocols, the data bits are automatically set at 8. Performer serial
port stop bits are automatically set at 1.

Table 2-4. Protocols and Applications

Protocol

Application

Performer Remote Control

Use this protocol when you are controlling the Performer from
the Performer Remote Control Panels.

Performer ASCII

Straightforward control of the Performer from a host computer,
using standard ASCII characters.

GVG Model 100 and 110

Use this protocol when you are controlling the Performer from
the Grass Valley Model 100 or 110 Production Switcher.

SMPTE 3245-E Remote Control System
for Television Equipment

Use this protocol when you are controlling the Performer from
a host computer using SMPTE 3245-E.