beautypg.com

Vertical interval strobe selection, Table 22. dipswitch s4 settings – Grass Valley Performer-HD User Manual

Page 24

background image

2-6

Performer-HD Instruction Manual

Section 2 — Installation

Vertical Interval Strobe Selection

Performer generates its own Vertical Interval strobe, which times the
switching of video so that switching occurs within a region of each video
field when there is no active video. Performer-HD generates this from look-
ing at the parallel video data, extracting vertical interval timing informa-
tion and sending out a pulse at a specific time during vertical interval. The
DIP switch S4 is used to tell the Performer-HD which line to switch on. The
choices are lines 1, 5, 6, 7, 8, and 9; corresponding to lines 563, 567, 568, 569,
570, and 571 in the second field.

To change the vertical interval strobe setting:

1.

Locate switch S2, segments 2, 7, and 8.

2.

Set for one of the three following conditions:

STANDALONE

—For Internal Strobe without providing external strobe

output from pin 4 of REMOTE connector:

Open

segments 2, 7, and 8

MASTER

—To provide External Strobe from pin 4 of the REMOTE

connector while using Internal Strobe:

open

segment 7;

Close

seg-

ment 8. This is the Factory setting.

SLAVE

—To receive External Strobe on pin 4 of the REMOTE connec-

tor:

Close

segment 2 and 7;

open

segment 8. This is for video signals

without sync information.

CAUTION

Do not set segments 7 and 8 to the “

C

” closed/ON position. This may cause a

system malfunction.

3.

Locate switch S4 and select a line to switch using

Table 2-2

. Line 1 (563)

is default.

Table 2-2. Dipswitch S4 Settings

Line

Selected

S4 Switch Position

1

2

3

4

5

6

7

8

1 (563)

C

C

C

C

C

O

O

O

5 (567)

O

C

O

C

C

O

O

O

6 (568)

C

O

O

C

C

O

O

O

7 (569)

O

O

O

C

C

O

O

O

8 (570)

C

C

C

O

C

O

O

O

9 (571)

O

C

C

O

C

O

O

O