beautypg.com

Serial control connections, Diagnostic connections, Serial control connections diagnostic connections – Grass Valley EC9535 v.1.1 User Manual

Page 12: Introduction, Rear connections, Fig. 1-5: serial control connections (rear view), Gsc node bus connector, Serial connections to control system

background image

4

Introduction

Rear Connections

to the attached router through serial connections. (See

Serial Control Connections

on page 4.)

For installation instructions, see

Making System Controller Connections

on page 11.

Fig. 1-4: GSC Node Bus Control Connection (Rear View)

Serial Control Connections

Figure 1-5 shows the serial control connections to the router. The ports are divided into two sets,
one primary control and one secondary control. Primary control is the connection to a router’s
primary control card. Secondary control is the connection to a router’s secondary control card
(which is optional for redundancy). Each set is further divided into connections that correspond
to router control systems: ‘CTRL 1’ corresponds to the primary control system and ‘CTRL 2’ corre-
sponds to an alternate control system. Only ‘CTRL 1’ is used. ‘CTRL 2’ is not used because there is
no alternate control system (i.e., backup system) for the SMS7000 system controller. However,
the connection is provided for future flexibility. For installation instructions, see

Making Router

Connections

on page 12.

Fig. 1-5: Serial Control Connections (Rear View)

Diagnostic Connections

The diagnostic connections enable the EC9535 to communicate with the UniConfig application.
UniConfig runs on a PC separate from the EC9535 and is used to perform system setup tasks,
and configure and monitor EC9535. (See

Configuration

on page 19.) See also the UniConfig

User’s Guide.

Diagnostic connections connect the EC9535 to the computer (PC) running the UniConfig appli-
cation. Two diagnostic connections are located on the rear of the EC9535, labeled ‘DIAG’. The
ports are divided into two sets: one primary and one secondary, as shown in Figure 1-6 on page
5. The
primary control connects to EC9535’s primary control card. The secondary control

VIDEO

REF 2

VIDEO

REF 1

ALARMS

TIME

CODE

LOOP

LOOP

LOOP

SEC

CTRL

LOOP

THRU

10/100 BT

10 B 2

PRI

CTRL

10 B 2

10/100 BT

AES

REF 1

AES

REF 2

DIAG

DIAG

E146905

GSC Node Bus

Connector

LOO

SEC

CTRL

LOOP

THRU

10/100 BT

10 B 2

PRI

CTRL

10 B 2

10/100 BT

AES

REF 1

AES

REF 2

DIAG

DIAG

CTRL 1

CTRL 2

CTRL 1

CTRL 2

Serial Connections

to Control System

This manual is related to the following products: