Level 3 RAID Instruction Manual

November 23, 2005

Chapter 4 Level 3 RAID Technical Specifications and Operating Limits

Copper cables are used to connect the RAID chassis with the expansion chassis.
Copper cables must meet the appropriate standards for 1-Gbit FC-AL loops. Such
cables are fully shielded, twin-axial, full-duplex cables. Cables greater than 10 meters
must be equalized; cables equal to or less than 10 meters do not need to be equalized.
Do not use copper cables longer than 2 meters.

Environmental limits

The system includes two temperature level sensors used to issue auto-warning and
auto-shutdown in case the over temperature limit is reached.

Life expectancies of components

Characteristic

Specification

Ambient temperature

Operating: 5°C to 40°C
Halting: -10°C to 60°C

Relative humidity
(without condensation)

Operating: 10% to 80%
Halting: 5% to 80%

Wet bulb temperature

Operating: 0°C to 27°C
Halting: -8°C to 29°C

Allowable vibration level

Operating: 0.25 G
Halting: 0.5 G

Item

Measurement

Battery backup unit
(Nearline only)

5 years

Fan (power supply)

50,000 hours