Data handling specifications, Ac power requirements, Size and weight – Grass Valley K2 Level 3 RAID Dec.09 2005 User Manual
Page 55: Cable lengths, Chapter 4, Data handling specifications ac power requirements, Size and weight cable lengths

November 23, 2005
Level 3 RAID Instruction Manual
55
Chapter
4
Level 3 RAID Technical Specifications
and Operating Limits
Data handling specifications
AC power requirements
If one of the two power supplies fails, the remaining supply and cord must support the
full load. Your rackmount cabinet must include AC power distribution that can handle
these values.
Size and weight
Cable lengths
It is recommended that you use the Fibre Channel cables shipped with your K2 Level
3 RAID Storage when making connections.
Optical cables must meet the appropriate standards for 2-Gb/s FC-AL loops. Such
cables are duplex LC cables with lengths up to 300m on 50/125
μ
m MMF, or up to
150m on 62.5/125
μ
m MMF.
Characteristic
Specification
Host interface
Fibre Channel
Data transfer rate
350 MB/s max
Number of host ports
4 ports
Cache memory
2 GB
Item
Measurement
Input voltage
100 to 240 VAC ±10% (x2), 50/60 Hz
Power consumption
680 to 1720 VA (For UPS choice, a safety allowance
of 30% of the power consumption is necessary.)
Labeling according to the energy
saving law
Class: G
Energy consumption efficiency: 0.10
Item
Measurement
Cabinet
dimensions
482 mm (19 “) W x 596 mm (23.5 “) D x 131 mm (5.2 “) H
(same for basic chassis and expansion chassis)
Weight
45 kg (99.2 pounds) or lighter
(same for basic chassis and expansion chassis)