4

Level 3 RAID Technical Specifications
and Operating Limits

Data handling specifications

AC power requirements

If one of the two power supplies fails, the remaining supply and cord must support the
full load. Your rackmount cabinet must include AC power distribution that can handle
these values.

Size and weight

Cable lengths

It is recommended that you use the Fibre Channel cables shipped with your K2 Level
3 RAID Storage when making connections.

Optical cables must meet the appropriate standards for 2-Gb/s FC-AL loops. Such
cables are duplex LC cables with lengths up to 300m on 50/125

μ

m MMF, or up to

150m on 62.5/125

μ

m MMF.

Characteristic

Specification

Host interface

Fibre Channel

Data transfer rate

350 MB/s max

Number of host ports

4 ports

Cache memory

2 GB

Item

Measurement

Input voltage

100 to 240 VAC ±10% (x2), 50/60 Hz

Power consumption

680 to 1720 VA (For UPS choice, a safety allowance
of 30% of the power consumption is necessary.)

Labeling according to the energy
saving law

Class: G
Energy consumption efficiency: 0.10

Item

Measurement

Cabinet
dimensions

482 mm (19 “) W x 596 mm (23.5 “) D x 131 mm (5.2 “) H
(same for basic chassis and expansion chassis)

Weight

45 kg (99.2 pounds) or lighter
(same for basic chassis and expansion chassis)