Primary raid chassis, Expansion chassis, Primary raid chassis expansion chassis – Grass Valley K2 Level 3 RAID Dec.09 2005 User Manual
Page 37: Interpreting front panel leds

November 23, 2005
Level 3 RAID Instruction Manual
37
Interpreting front panel LEDs
Primary RAID chassis
Expansion chassis
Operating
Condition
Power
LED
Service
LED
Meaning
Running
On
Off
DC power is being supplied to the system.
On
On
Temperature alarm
On
On
Resources in online status are missing or invisible, as in one
or more of the following:
- The controller is down.
- At least one Backup Battery Unit on power supply is faulty.
- At least one fan on the power supply is faulty.
- One or more power alarms are in effect
- A disk drive (RAID chassis or Expansion chassis) is faulty.
- An Expansion adapter is faulty.
- The logic is occluded.
- The logic is degraded.
- The logic is being restored.
- The logic is being restored to the hot spare.
Starting
up
On
Flash
Chassis is between power-on and ready state.
On
Flash (5 sec.)
and Off (7 sec.)
Backup data is lost due to excess of data retaining period in
Backup Battery Unit. (Nearline only)
Shutting
down
Flash
Off
Shutdown sequence is being executed.
Off
Off
Shutdown sequence is complete.
Operating
Condition
Power
LED
Service
LED
Meaning
Running
On
Off
The chassis is operating normally.
Off
On
The FAULT LED is lit on one or more disks
Fault detected on one or more power supplies
High temperature on one or more Expansion chassis
Fault on one or more fans
One or more temperature sensors failed
Package failure (ESD communication failure detected on at
least one port)
Starting
up
Off
Off
System startup
On
Off
Startup successful. Entering ready state.
Off
On
—> Off
The ESD is successfully initialized and operating normally.
Off
On
Faulty condition or illegal switch setting detected on ESD.