background image

2-20

Vertigo XG & iTX Integration User Guide

Configuration Procedures

4.

Click Save and then Close.

A

CTIVE

Select the Active button to enable (green LED) or disable (grey LED) the
VertigoXG plugin.

A

DDRESS

Enter the IP address of the VertigoXG device.

P

ORT

5006 is the port number on which iTX is to communicate with Xplay.

A

UTOMATION

D

ELAY

(

MS

)

iTX uses this value to determine how much earlier than the scheduled time
Take and Clear commands are sent in order to compensate for small
communication delays when sending commands.

OFF D

ELAY

(

FRAMES

)

Specifies the number of frames prior to the end of the XG event that the Clear
command will be triggered, so as to offer the page’s Default Out animation a
chance to playout.

O

UTPUT

C

HANNEL

Currently not used.

E

NABLE

S

LAVE

D

EVICE

Enable this setting when a Master-Slave setup is used and the Master and
Slave each have their own instance of an XG.

E

NABLE

TS C

OMMANDS

Not applicable when using a downstream external Vertigo XG.

Ensure that this setting is off.