beautypg.com

Grass Valley Vertigo XG Integration v.2.3 User Manual

Page 19

background image

Vertigo XG & iTX Integration User Guide

2-9

Configuration Procedures

4.

Click Save and then Close.

A

CTIVE

Select the Active button to enable (green LED) or disable (grey LED) the
VertigoXG plugin.

A

DDRESS

Enter the IP address of the playout server on which Xplay is running.

P

ORT

5006 is the port number on which iTX is to communicate with Xplay.

A

UTOMATION

D

ELAY

(

MS

)

iTX uses this value to determine how much earlier than the scheduled time
Take and Clear commands are sent.

When

E

NABLE

TS C

OMMANDS

is selected, an automation delay of at least

500ms is recommended.

OFF D

ELAY

(

FRAMES

)

Specifies the number of frames prior to the end of the XG event that the Clear
command will be triggered, so as to offer the page’s Default Out animation a
chance to playout.

O

UTPUT

C

HANNEL

Currently not used.

E

NABLE

S

LAVE

D

EVICE

Enable this setting when a Master-Slave setup is used and the Master and
Slave each have their own instance of an XG.

E

NABLE

TS C

OMMANDS

When selected, the Take and Clear commands are sent to the XG as
determined by the Automation Delay setting with a timestamp indicating
when the command will execute. This approach compensates for small
delays in communication with the XG and ensures frame accuracy.

This manual is related to the following products: