Grass Valley Vertigo XG Integration v.2.3 User Manual
Page 19

Vertigo XG & iTX Integration User Guide
2-9
Configuration Procedures
4.
Click Save and then Close.
A
CTIVE
Select the Active button to enable (green LED) or disable (grey LED) the
VertigoXG plugin.
A
DDRESS
Enter the IP address of the playout server on which Xplay is running.
P
ORT
5006 is the port number on which iTX is to communicate with Xplay.
A
UTOMATION
D
ELAY
(
MS
)
iTX uses this value to determine how much earlier than the scheduled time
Take and Clear commands are sent.
When
is selected, an automation delay of at least
500ms is recommended.
OFF D
ELAY
(
FRAMES
)
Specifies the number of frames prior to the end of the XG event that the Clear
command will be triggered, so as to offer the page’s Default Out animation a
chance to playout.
O
UTPUT
C
HANNEL
Currently not used.
E
NABLE
S
LAVE
D
EVICE
Enable this setting when a Master-Slave setup is used and the Master and
Slave each have their own instance of an XG.
E
NABLE
TS C
OMMANDS
When selected, the Take and Clear commands are sent to the XG as
determined by the Automation Delay setting with a timestamp indicating
when the command will execute. This approach compensates for small
delays in communication with the XG and ensures frame accuracy.