Pre-installation requirements – Extreme Networks BlackDiamond 12804 User Manual
Page 61
Rack-Mounting the BlackDiamond 12804 Chassis
BlackDiamond 12800 Series Switches Hardware Installation Guide
61
Pre-installation Requirements
The following tools, equipment, and resources are required for installing the BlackDiamond 12804
chassis:
●
ESD-preventive wrist strap (provided)
●
19-inch helper bracket (provided)
●
For installing the chassis in a mid-mount position in the rack:
■
Optional BlackDiamond 8806/12804 mid-mount kit, part number 65046. Order this kit separately
from the chassis.
■
#2 Phillips screwdriver
●
Rack-mount screws appropriate for your organization’s rack system, as follows:
■
4 screws to attach the helper bracket
■
12 screws to secure the BlackDiamond 12804 chassis in the rack
The screw size will vary based on your organization’s rack system; screws are not provided.
●
Screwdriver appropriate for the rack-mounting screws you will use
The screwdriver size will vary based on the requirements of your organization’s rack system.
Attaching the BlackDiamond 12804 Mid-Mount Brackets
To install the BlackDiamond 12804 switch in a mid-mount position in the rack, attach the optional mid-
mount brackets.
To attach the mid-mount brackets:
1
Place the empty BlackDiamond 12804 chassis in an upright position on a secure flat surface.
CAUTION
The BlackDiamond 12804 chassis weighs almost 65 pounds. Proper lifting and moving of the chassis requires two
people.
2
Determine the locations for the mid-mount brackets.
NOTE
Each side of the chassis has two sets of mounting holes to provide two positions for attaching the mid-mount
brackets.
3
Identify the left and right brackets.
Each mid-mount bracket is clearly marked for placement on either the right or left side, as viewed
from the front of the chassis.
4
On each side of the chassis, attach the appropriate mid-mount bracket using the eight screws
provided in the kit (see