Setting Up the CommLink FXC-S201

CommLink FXC-S201 Fiber Optic Intercom Link Switch Configuration

CommLink FXC-S201 Fiber Optic Intercom Link

Switch

Configuration

The following decision tree traces the setting of the CommLink FXC-S201 Fiber Optic
Intercom Link configuration switches.

• Set the System mode - Clear-Com (CC) or RTS

• Decide if you are operating in 2W or 4W

• If in 2W set your power to External (EXT) or Internal (INT) - this decides between using

the power from the intercom system or Belt Packs (EXT) or providing internal power
from the CommLink FXC-S201 Fiber Optic Intercom Link with the 12 Volt power supply
(INT)

• If in 4W set the switch depending on whether you have an Intercom Matrix Station

(STA) or Matrix (MTX) attached to the CommLink FXC-S201 Fiber Optic Intercom Link

Fig. 3-7: Configuration Switch Decision Tree