beautypg.com

Service, Troubleshooting – Grass Valley 2020ADC A-To-D User Manual

Page 27

background image

2020ADC — Instruction Manual

27

Service

Service

The 2020ADC modules make extensive use of surface-mount technology
and programmed parts to achieve compact size and adherence to
demanding technical specifications. Circuit modules should not be ser-
viced in the field unless as directed otherwise by Customer service.

Troubleshooting

If your module is not operating correctly, proceed as follows:

Check frame and module power. If power is not present, check the fuse
on the +24 V input to the module as illustrated in

Figure 13

.

Check for presence and quality of input signals.

Verify that source equipment is operating correctly.

Check cable connections.

Figure 13. Location of Module Fuse

Refer to

Figure 6

for the location of PWR LED and

Table 3 on page 15

for

proper LED indications.

If the module is still not operating correctly, replace it with a known good
spare and return the faulty module to a designated Grass Valley repair
depot. Call your Grass Valley representative for depot location.

Refer to the

Contacting Grass Valley

at the front of this document for the

Grass Valley Customer Support Information number.

8024_08

F1

Fuse: 2 A FAST, 125 V