Verifying transceiver modules, Diagnosing transceiver modules, Troubleshooting system exceptions – H3C Technologies H3C SecPath U200-A U200-M U200-S User Manual
Page 58: Configuring the exception handling methods, Displaying the exception handling method

49
Verifying transceiver modules
To verify transceiver modules, you can use the display transceiver interface command to display the key
parameters of the transceiver modules, including transceiver module type, connector type, central
wavelength of the laser sent, transfer distance, and vendor name.
To display the transceiver module information:
Task Command
Remarks
Display key parameters of the
transceiver module in a specified
interface.
display transceiver interface
[ interface-type interface-number ]
Available for all transceiver
modules
Diagnosing transceiver modules
The UTM device provides the alarm function for transceiver modules for diagnosis.
To display the alarm information about transceiver modules:
Task Command
Remarks
Display the current alarm
information of the transceiver
module in a specified interface.
display transceiver alarm interface
[ interface-type interface-number ]
Available for all transceiver
modules
Troubleshooting system exceptions
Configuring the exception handling methods
You can use one of the following methods to handle system exceptions:
•
reboot—The UTM device reboots to recover from the error condition.
•
maintain—The UTM device stays in the error condition and does not take any measure to recover
itself, so you can collect complete data, including error messages, for diagnosis.
To configure the exception handling method:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Configure the exception
handling method for the
system.
system-failure { maintain |
reboot }
Optional.
By default, the system uses the
reboot method when an exception
occurs.
Displaying the exception handling method