Symptom, Solution – H3C Technologies H3C WX6000 Series Access Controllers User Manual

Page 23

background image

7-5

4) If the problem still exists, contact the service engineer.

The Main Control Board on the WX6103 Access Controller Cannot
Be Started

Symptom

The WX6103 access controller main control board cannot be started, and you cannot enter the user

prompt.

Solution

Check that:

1) The main control board can be powered on, and RUN LED of the corresponding slots blinks,

indicating the main control board is working normally. For description of the LED statuses, see the

LED description in the installation guide supplied with the AC.

2) The memory chip is installed properly to the main control board, and the memory chip or socket is

polluted. In the latter case, clean them with specific cleaning material, and then re-insert the

memory chip.

3) The CF card is properly connected.

4) If the problem still exists, contact the service engineer.