Ge interface card problem of the wx3024, Symptom, Solution – H3C Technologies H3C WX6000 Series Access Controllers User Manual

Page 20: Over-temperature alarm

background image

7-2

8) Connect the two ends of the optical fiber to the TX and RX ends of the same optical transceiver to

check connectivity of the optical interfaces. If the optical interfaces still cannot connect to the

network, connect the optical fiber in the same way to the optical interfaces that work normally. If the

optical interfaces still cannot connect to the network, the optical transceiver is faulty. Use the other

optical transceiver or replace it with another one, and then perform the same test.

9) The length of the optical fiber does not exceed the distance supported by the optical transceiver.

10) If the problem still exists, contact the service engineer.

10-GE Interface Card Problem of the WX3024

Symptom

After you insert the 10-GE interface card to the WX3024, the card cannot work.

Solution

Check that:

1) The AC starts up completely and you can see the user prompt.

2) Enter

the

oap connect slot 0 command in user view on the WX3024.

3) You have properly installed the 10-GE interface card to the MOD slot of the WX3024, and fastened

the captive screws.

4) The installation prompt is printed at the terminal upon insertion of the interface card. If not, insert

the card to another MOD slot. If the problem still exists, the 10-GE interface card is faulty.

5) If the MOD LED of the slot installed with the 10-GE interface card on the front panel blinks yellow,

the interface card is faulty. Replace it with another one.

6) The 10-GE interface card is supported by the WX3024. For optical transceivers supported by the

WX3024, see Appendix A Specifications of Optional Interface Modules in the installation manual

supplied with the WX3024.

7) The optical fiber is correct and works well. Otherwise, replace it with another one.

8) Insert an optical transceiver to the 10-GE interface card. Then connect the TX and RX ends of the

optical transceiver with an optical fiber, and check the MOD LED on the front panel. If the LED is

not steady green, use another optical transceiver to do the same test. If the optical transceiver

works normally on other interface cards, the 10-GE interface card is faulty.

9) Contact the service engineer after the above steps.

Over-Temperature Alarm

Symptom

The AC prompts an over-temperature alarm, and the status LED or alarm LED indicates an alarm. For

description of the LED statuses, see the LED description in the installation guide supplied with the AC.

Solution

Check that:

1) The AC starts up completely.

2) The operating temperature of the AC falls in the range 0°C to 45°C (32°F to 113°F).

3) All fans run normally.

4) Execute

the

display environment [ cpu ] command to check the temperatures of relevant

components of the AC.