2

Table 2

describes the power modules' protection status and recovery for

each protection action.

Table 2 Power modules' protection status and recovery for each
protection action

Protection
action

Protection
status

Recovery

Over-voltage
protection

The power
module is
latched off.

The power module cannot
recover automatically.
To recover the power module:

1.

Switch off the module
and disconnect the
power cord.

2.

Reconnect the power
cord and power on the
module.

Short-circuit
protection

Current-limiting
protection

Over-temperat
ure protection

The power
module stops
providing
power.

The power module recovers
automatically after the
temperature drops to the
acceptable range.