H3C Technologies H3C S9500E Series Switches User Manual
Page 77

67
Field Remarks
RX CDR loss of lock
Receiving CDR loss of lock.
TX fault
Transmission error.
TX not ready
The transmission status is ready.
TX CDR loss of lock
Transmission CDR loss of lock.
Module not ready
The module is not ready.
APD supply fault
Avalanche Photo Diode (APD) supply error.
TEC fault
Thermoelectric Cooler (TEC) error.
Wavelength unlocked
Wavelength loss of lock.
RX power high
The received optical power is high.
RX power low
The received optical power is low.
TX power high
The transmitted optical power is high.
TX power low
The transmitted optical power is low.
TX bias high
The transmitted bias current is high.
TX bias low
The transmitted bias current is low.
Temp high
The temperature is high.
Temp low
The temperature is low.
Voltage high
The voltage is high.
Voltage low
The voltage is low.
Transceiver info I/O error
Transceiver information read and write error
Transceiver info checksum error
Transceiver information checksum error
Transceiver type and port configuration mismatch
The type of the transceiver module does not match the
port configuration.
Transceiver type not supported by port hardware
The port does not support this type of transceiver
modules.
# Display the currently measured values of the fault detection parameters of the transceiver module
plugged in interface GigabitEthernet 3/0/1.
GigabitEthernet3/0/1 transceiver diagnostic information:
Current diagnostic parameters:
Temp(°C) Voltage(V) Bias(mA) RX power(dBM) TX power(dBM)
36 3.31 6.13 -35.64 -5.19
Table 23 Command output
Field Description
transceiver diagnostic information Digital diagnosis information of the transceiver module on the interface.
Current diagnostic parameters
Current diagnosis parameters.
Temp.(°C)
Digital diagnosis parameter—Temperature, in °C, accurate to 1°C.
Voltage(V)
Digital diagnosis parameter—Voltage, in V, accurate to 0.01 V.