Lpu status leds, Mpu status leds, Lpu leds – H3C Technologies H3C S9500E Series Switches User Manual
Page 123: Link/act led

113
LED Status
Description
Steady on
A link is present.
ACT
Off
No data is being transmitted or received.
Flashing
Data is being transmitted and/or received.
LPU status LEDs
Table 45 LPU status LED description
LED Status
Description
RUN (green)
Steady on
The LPU is faulty.
Off
The LPU is faulty or not in position.
Flashing (8 times per second)
The LPU is registering or starting up.
Flashing (1 time per second)
The LPU is operating properly.
ALM (red)
Steady on
An alarm has occurred.
Off
No alarm has occurred.
MPU status LEDs
Table 46 MPU status LED description
LED Status
Description
SFS (green)
Steady on
The switching fabric module is in working state.
Off
The switching fabric module is in standby state.
ACT (green)
Steady on
The MPU is in active state.
Off
The MPU is in standby state.
RUN (green)
Flashing
The MPU is operating properly.
Steady on
The MPU is faulty.
Off
The MPU is faulty or not in position.
ALM (red)
Steady on
An alarm has occurred.
Off
No alarm has occurred.
LPU LEDs
LINK/ACT LED
Each interface on the following LPUs has a LINK/ACT LED:
•
LSR2GT24LEB1
•
LSR1GT24LEC1