Rotating gobo indexing error:

The gobo is not located in the default position after start-up or after a reset command. This

message will appear after a fixture reset if the gobo positioning magnetic-indexing circuit

malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure

(defective motor or a defective motor IC drive on the main PCB).

Fix Gobo-wheel error:

This message will appear after the reset of the fixture if the magnetic-indexing circuit

malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its drive

circuit on the main PCB). The fix gobo wheel is not located in the default position after the

reset.

Prism-wheel error:

This message will appear after the reset of the fixture and if the magnetic-indexing circuit

malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its

driver circuit on the main PCB). The Prism wheel is not located in the default position after

the reset.

Focus-error:

This message will appear after the reset of the fixture and if the magnetic indexing circuit

malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its

driver circuit on the main PCB). The focus motor is not located in the default position after

the reset.

Shutter, Strobe error:

(Shutter, Strobe-wheel error) This message will appear after the reset of the fixture if the

yoke’s magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the

stepping-motor is defective (or its driving IC on the main PCB). The Shutter, Strobe -wheel is

not located in the default position after the reset.

Iris-error:

This message will appear after the reset of the fixture and if the magnetic indexing circuit

malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its