Syslog Servers
Configure up to 4 external syslog servers. This functionality is compatible with any
syslog server program on the internet.
Select the enable messages option to turn on the syslog function.
Select the correct line number.
Configure the ip address or the host name of the pc or server with the syslog
software installed.
Set the port number specified by the syslog software.
Set the facility setting you wish to log.
Select to record the data to the WLO’s internal Event log or the Traffic Log. These 2
logs have up to 2 MB of storage space available to them.
Logging Configuration
Configure the logging levels for the WLO. This section allows for a different logging
configuration for each log location. This allows for a better reporting tool, and no
duplicate log entries.
The first option is the log level. This uses the standard log / facility levels for logging.
Levels: 0=Emergency, 1=Alert, 2=Critical, 3=Error, 4=Warning, 5=Notification,
6=Information, 7=Debugging. The log level will determine how many log entries
the WLO will produce. Setting a low number, the logs will only show minimum
entries related to service or attack issues. Using a higher number, will show more
log entries related to simple traffic flow. Level 7, debugging is used for support
purposes only, as it will log everything, including key strokes.