beautypg.com

Allstar Performance ALL81200-02 User Manual

Page 2

background image

Allstar Performance 8300 Lane Drive, Watervliet MI 49098

Phone: (269) 463-8000 Fax: (800) 772-2618 www.allstarperformance.com

Adjustable Vacuum Advance

Connect the vacuum advance module to a ported

vacuum outlet above the throttle plates. The vacuum

advance on this unit can be adjusted by inserting a

3/32” Allen wrench into the canister inlet which houses

an adjustable Allen head screw. See Figure 1. Before making

adjustments, turn the screw clockwise until fully seated.

Turning the screw clockwise retards advance,

turning it counter clockwise increases advance.

Timing Advance Chart

Break-In Period Required

• Prior to completion of installation, the distributor gear should have received a coating of zinc or moly based grease (grease

sold separately). It is the responsibility of the installer to apply this grease.

• Do not use synthetic oil during break-in period. Once break-in period is complete, any suitable oil of choice can be used.

• On

modifi ed engines with oil pressure above 70 psi (cold), the gear should be broken-in with racing grade mineral oil.

• Monitor gear wear after several hours of break-in. Check the gear for proper mesh, alignment, and wear.

Limited Warranty

Manufacturer’s obligation for warranty returns shall be limited to repairing, replacing, or crediting as its option, any parts found

to be defective. Manufacturer will not be liable for charges and/or other expenses incurred, nor shall it be liable for damages or

injury to persons or property resulting from the misuse or improper installation of any part subject to this warranty. The warranty

contained herein is expressly in lieu of any and all other warranties, including any implied warranty of merchantability or fi tness

for any particular purpose.

Fig. 1

Adjusting Vacuum Advance

Turns Out

Degrees

0

2

4

6

8

10

1

5

5.1

5.6

5.6

6

6.5

2

5.2

5.2

5.9

6

6.6

7

3

5.5

5.5

6.2

6.5

7

7.2

4

5.8

5.9

6.5

6.7

7.2

7.5

5

6

6.1

6.7

7

7.5

7.8

6

6.2

6.3

7

7.4

7.8

8.2

7

6.5

6.5

7.4

7.8

8.2

8.6

8

6.8

6.8

7.8

8.3

8.6

9.1

9

7

7.1

8

8.5

9

9.5

10

7.4

7.4

8.4

8.9

9.4

10

11

7.6

7.8

9

9.2

10

10.4

Amount of vacuum at canister

Turns Out

Degrees

0

2

4

6

8

10

12

8

8.3

9.2

9.8

10.4

10.8

13

8.2

8.7

9.6

10.2

10.6

11.3

14

8.5

9.2

10.2

10.6

11.2

11.6

15

9

9.6

10.6

11.2

11.6

12.4

16

9.6

10.2

11.2

11.7

12.4

12.8

17

10.4

10.8

11.8

12.3

13

13.5

18

11

11.4

12.5

13.1

13.5

14.4

19

11.8

12

13.4

13.8

14.4

15.1

20

12.5

12.6

14.2

14.6

15.2

16.1

21

13.5

13.2

15.3

15.5

16.6

17.4

22

14

14.6

16.7

17

17.5

19.4

Amount of vacuum at canister

FORM 1030

Page 2 of 2

Rev.071907