Maintenance – Allmand Brothers NL PRO II User Manual
Page 49
49
MAINTENANCE
The Safety messages that follow have
WARNING level Electrocution Hazards.
Only qualified electricians should ser-
vice or perform replacement proce-
dures. Ballast and capacitors are capa-
ble of discharging high voltage. Always
use appropriate personal safety cloth-
ing and gear when servicing electrical
components.
High voltage is present when engine is
running. Never attempt to service elec-
trical components while engine is run-
ning.
Do not operate the light tower if the in-
sulation on the electrical wiring is cut
or worn, or if bare wires are exposed.
Repair or replace damaged wiring be-
fore starting the engine.
1
2
1. Lamp Ballast
2. Capacitors
HYDRAULIC PUMP
Hydraulic Oil Specifications
Adding Hydraulic Oil
Fill the reservoir with aviation hydraulic fluid or
any clean hydraulic fluid having a viscosity index
that is suitable for the climate conditions in which
the unit will be operated. Standard units are sup-
plied with automatic transmission fluid (ATF), and
arctic units are supplied with aviation hydraulic
fluid (see Figure 31).
Figure 31
Figure32