Pamtc,comp,resetall, Pamtc,comp,resetcal, Pamtc,comp,resetdamp – Airmar LB150 User Manual
Page 46
LB150 WeatherStation Technical Manual revision 0.013
Proprietary and Confidential
PRELIMINARY - DRAFT
43
$PAMTC,COMP,RESETALL
Summary
Reset the user calibration coefficients and damping control to the default values.
Syntax
$PAMTC,COMP,RESETALL*hh
Reply
The weather station will reset the user calibration coefficients and damping
control (fields 1-9) and reply with:
$PAMTR,COMP,RESETALL,
<1>,<2>,<3>,<4>,<5>,<6>,<7>,<8>,<9>*hh
where fields <1> through <9> contain the data from the weather station’s
nonvolatile EEPROM, as defined in the “Q”, Query Command.
$PAMTC,COMP,RESETCAL
Summary
Reset the user calibration coefficients to the default values.
Syntax
$PAMTC,COMP,RESETCAL*hh
Reply
The weather station will reset the user calibration coefficients (fields 1 – 6) and
reply with:
$PAMTR,COMP,RESETCAL,
<1>,<2>,<3>,<4>,<5>,<6>,<7>,<8>,<9>*hh
where fields <1> through <9> contain the data from the weather station’s
nonvolatile EEPROM, as defined in the “Q”, Query Command.
$PAMTC,COMP,RESETDAMP
Summary
Reset the user damping control to the default values.
Syntax
$PAMTC,COMP,RESETDAMP*hh
Reply
The weather station will reset the user damping control (fields 7-9) and reply
with:
$PAMTR,COMP,RESETDAMP,
<1>,<2>,<3>,<4>,<5>,<6>,<7>,<8>,<9>*hh