XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style

19 of 36

4-3 Basic Setting of the Filling Level in the Conveyor Hopper

The filling level in the conveyor hopper is mainly determined by the level sensor.

Figure 6: Conveyor Hopper


Filling Level Too Low

1. Using a screwdriver, turn the adjustment screw of the level sensor (A) ¼

rotation counter-clockwise.

2. Check the filling level during the next conveying procedure.

3. Repeat the process until the desired filling level in the conveyor hopper is

reached.

Filling Level Too High

1. Using a screwdriver, turn the adjustment screw (A) of the level sensor ¼

rotation clockwise.

2. Check the filling level during the next conveying procedure.

3. Repeat the process until the desired filling level in the conveyor hopper is

reached.