XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style

14 of 36

2-4 Connecting the Compressed Air Supply

Before connecting the compressed air supply, check the following:

Check compressed air piping for correct installation and assembly.

Check the fittings, length and quality of the hose connections for

agreement with requirements.

Check all compressed air lines for leakages.

You need a compressed air supply with 70-90 psi (5-6 bar) system pressure.

The air should be free of oil and water.

1. Find the compressed air hose, which has

been supplied.

2. Connect it to the venturi assembly and to

the control and maintenance unit.

3. The compressed-air hose is firmly pressed

into each connecting socket.

4. Connect the control and maintenance unit

to the compressed air supply. Max. input
pressure 145 psi (10 bar) system pressure.

5.

Set the pressure on the pressure reducer
at 70-90 psi (5-6 bar).

Maximum input pressure: 145 psi (10 bar) system
overpressure.

Maximum output pressure: 90 psi (6 bar).

Figure 3: Venturi Assembly