beautypg.com

Hn – disconnection, Hn – mnp10 connection speed, Kn – flow control – Westermo TD-32 User Manual

Page 22

background image

22

6178-2203

Hn – Disconnection

The command makes the modem either connect to or disconnect from the line.

H0

Disconnection ”on-hook”.

H1

Connection ”off-hook”.

Please also refer to S7

*Hn – MNP10 connection speed

This command controls the initial line speed during connection, between two MNP10 modems. The
value is written to S28 bit 6 and 7.

*H0

Connection is executed at maximum available speed. (Default)

*H1

Connection is executed at 1 200 Baud.

*H2

Connection is executed at 4 800 Baud.

Please also refer to AT\N

In – Identification Report

The command reports the requested result to the DTE connection, the terminal or the computer.

I0

Reports product code.

I1

Reports a precomputed checksum.

I2

Reports a precomputed checksum and compares it to the value stored in the program (I1).

I3

Reports firmware revision.

I4

Reports product identification information.

I5

Reports Country Code parameter.

I6Reports modem data pump model and internal code revision.

&Kn – Flow Control

This command sets the flow control between the modem and the terminal.
The value is written to S39 bit 0, 1 and 2.

&K0

Disables flow control.

&K3

Enables RTS/CTS flow control. (Default)

&K4

Enables XON/XOFF flow control.

&K5

Enables transparent XON/XOFF flow control.

&K6Enables both XON/XOFF and RTS/CTS flow control.