beautypg.com

Description of commands, A/ – re-execute command, A – answer – Westermo TD-32 User Manual

Page 15: An – select maximum mnp block size, An – interrupt connection negotiation, Bn – selecting ccitt or bell

background image

15

6178-2203

Description of commands

The modem can be configured and controlled with the AT-commands listed below.

A/ – Re-execute command

This command differs from the others since it will not be preceded by ”AT” and also not terminated by
ENTER.

A – Answer

The modem will wait for a carrier for the time that was specified in S7.

Please also refer to ATDn, S0, S1, S7, S8, S9, S30

\An – Select Maximum MNP Block Size

This command controls the size of data blocks used during connections with MNP, error corrected
links. The value is written to S40 bit 6 and 7.

\A0

64 characters.

\A1

128 characters.

\A2

192 characters. (Default)

\A3

256 characters.

Please also refer to AT\N

&An – Interrupt connection negotiation

Usually the modem will abort the connection negotiation if characters are sent to the serial port dur-
ing negotiation phase.
This command gives a possibility to ignore incoming characters.

&A0

Abort connection negotiation when characters are sent to the serial port. (Default)

&A1

The modem will ignore characters on the serial port during negotiation phase.

Please also refer to AT&D

Bn – Selecting CCITT or BELL

For historical reasons the American standard for 300 and 1200 baud is different than the international.

B0

CCITT-mode (European standard) (Default)

B1

BELL-mode (American phone company)

Please also refer to ATFn, S27