beautypg.com

Westermo GS-01 User Manual

Page 30

background image

30

6195-2201

+IFC – DTE-DCE local flow control

This command is used to control the operation of local flow control between the DTE
and DCE.

AT+IFC=,

* < DCE_by_DTE >:

0

none

Supported

1

Xon/Xoff local circuit 103

Not supported

2

RTS

Supported

3

Xon/Xoff global on circuit 103 Not supported

Important note: When this parameter is set to 2 (DTE invokes flow control through RTS)

the behavior of the DCE is the following:
If the DCE has never detected RTS in high (or ON) condition since
startup then it ignores RTS, assuming this signal is not connected.
As soon as DCE detects RTS high, then this signal acts upon it.
Therefore subsequent RTS transition to OFF will prevent DCE from
sending any further data in online and in offline as well.
This behavior allows the user to use the default settings (hardware flow
control) and let RTS disconnected. In the case RTS is connected and is
high at least once then it acts upon DCE.

< DTE_by_DCE >:

0

none

Supported

1

Xon/Xoff circuit 104

Not supported

2

CTS

Supported

When this parameter is set to 0 (none) then CTS is kept high all the time.

Application to GSM

AT+IFC?

GSM to application

+IFC: 2,2

Current values

OK

Application to GSM

AT+IFC=?

GSM to application

+IFC: (0,2),(0,2)

Possible values

OK

Application to GSM

AT+IFC=0,0

GSM to application

OK

New values