Westermo GS-01 User Manual
Page 24
24
6195-2201
Application to GSM
AT+CPBW=,”0345221100”,
Write at the first free location
129,”SOS”
GSM to application
+CME ERROR: 20
Phonebook full
Application to GSM
AT+CPBW=57,”112”,
Write at loc 57 (wrong)
129 ,”WM”
GSM to application
+CME ERROR: 21
Invalid index
Application to GSM
AT+CPBW=7,
Write at loc. 7 a long Phone
”012345678901234567
number (21 digits)
890”,129 ,”WAVE”
GSM to application
+CME ERROR: 26
Phone too long
Application to GSM
AT+CPBW=7,
Write at loc. 7 a long Text
”0122334455”,129 ,
(11 characters)
”WAVECOM TEL”
GSM to application
+CME ERROR: 24
Text too long
When the fixed dialling phonebook (FDN) is locked , this command is not allowed.
Moreover, when FDN is unlocked, PIN2 is required to write in the FDN phonebook.
But if PIN2 authentification has been done during the current cession ,
+CPBW command with FDN is allowed .
Application to GSM
AT+CPBS=”FD”
Choose FDN
GSM to application
OK
Application to GSM
AT+CPBW=5,”01290917”,
Write in FDN at location 5
129,”Jacky”
GSM to application
+CME ERROR:17
SIM PIN2 is required
Application to GSM
AT+CPIN?
GSM to application
SIM PIN2
SIM PIN2 is required
Application to GSM
AT+CPIN=5678
Enter SIM PIN2
GSM to application
OK
Application to GSM
AT+CPBW=5,”01290917”,
Write in FDN at location 5
129,”Jacky”
GSM to application
OK
Now writing in FDN is allowed