Westermo GS-01 User Manual
Page 13
13
6195-2201
ATS0 – Automatic answer
This S0-parameter controls the automatic answering feature of the mobile.
Application to GSM
ATS0=2
Automatic answer after 2 rings
GSM to application
OK
Application to GSM
ATS0?
Current value
GSM to application
002
Always 3 characters with leading
OK
zeros
Application to GSM
ATS0=0
No automatic answer
GSM to application
OK
Command valid
All others S-parameters (S6,S7,S8 ...) are not implemented.
+CICB – Incoming Call Bearer
Command syntax:
AT+CICB=
This specific command is used for incoming call type when no incoming bearer is given
(single numbering scheme, see +CSNS).
0: Data
1: Fax
2: Speech
Application to GSM
AT+CICB=1
If no incoming bearer, force a fax
call
GSM to Application
OK
Command accepted
Application to GSM
AT+CICB=2
If no incoming bearer, force a
speech call
GSM to Application
OK
Command accepted
Application to GSM
AT+CICB?
Interrogate value
GSM to Application
+CICB: 2
Default incoming bearer:
speech call
Application to GSM
AT+CICB=?
Test command
GSM to Application
+CICB: (0-2)
Speech, data or fax default