Section 4 Regulatory Specifications and Declarations

22

It is the responsibility of the system integrator or network operator to ensure
that installations meet Telecommunication specifications in support of

interconnect agreements.

4.3

Essential Compliance Information

This section documents miscellaneous points that should be observed to

ensure the proper and safe use of this product worldwide.

4.3.1 Safety

Users of this product, and service personnel, must refer to the Safety

information included in

Section

1 Warnings and Cautions on page 7

and in

the documentation of any host computer into which the board is to be

installed.

The SCPI2S and SPCI4 boards are approved for installation in a host

computer, and with host attachments, which are covered by a relevant type
approval of their own.

It is a condition of approval that the power required by the host and the total

of all adapter boards installed within the host environment, together with any
auxiliary apparatus, does not exceed the power specification as stated in the

Technical reference Manual of the host computer. The power required by this

board is 1.5A typical, 2.0A maximum, @ +5V.

It is not intended for this product to be installed in a home or residential

environment. It is not intended for this product to be installed or operated in

a stressful or inordinary environment such as industrial sites, medical

applications, or in flammable/explosive environments.

4.3.2

USA and Canada Specific Safety aspects

This SCPI2S and SPCI4 boards are for use only with UL listed computers that

have installation instructions detailing user installation of card cage

accessories.

To comply with the relevant safety requirements in these countries,
connection of this equipment to the public network MUST be via a UL listed

channel service unit (i.e. the board must NOT be directly connected to the

external public line).

4.3.3 EMC

Installation of Cables

In order to ensure that the EMC performance of the products meet regulatory

requirements: -

Cables used for the PCM Interface Ports, marked L1 to L4, shall be twisted-
pair screened cables, grounded at both ends.

Cables used for the SS7 Serial Interface Ports (SPCI2S), marked AUX, shall

have the ferrite clamps, provided with the product, installed close to the
connector backshell.