7

(Optional) Wire the Click 203

If you are using the Click 203 UPS and battery module,

follow the steps below to correctly wire it:
1 Wire AC power into the UPS module by connecting

the AC line (black wire) to the L (+) terminal.

2 Connect the AC neutral (white wire) to the N (-)

terminal.

3 Wire the supplied red wire from the + Battery

terminal on the UPS to the + OUT terminal on the

battery.

4 Wire the supplied black wire from the - Battery

terminal to the - DC terminal on the battery.

5 DC power can be wired out of the UPS module

by connecting to the + and - OUT DC 24V 2A

terminals.

6 Short R1 to R2. If you don’t, the UPS will not switch

over to the battery when the power goes out.

DC Out

AC In