Use on-device configuration features
Next, use the device’s configuration features to
make sure the Click 301 is wired and working
properly. The Click 301 has three LEDs that moni-
tor device activity and help you select operating
modes, as well as a push-button, labeled Mode
Switch, also used for operating modes.
1 Check LEDs to make sure the device has power.
2 Autobaud device to make sure it can talk to the
sensor or other attached serial device (see table).
Hold the push-button to cycle through modes, then release when the desired mode is reached.
LED operating mode indicating functions:
Selection Operating mode
Running
Completed
Autobaud – Release push-button when
green LED is solid to autobaud to sensor.
Failure
Success
Reset – Release push-button when red LED
is blinking to reset to factory defaults.
Note. On some devices, the yellow LED may replace the green LED in the autobaud process—that is, the
yellow LED selects the autobaud process, is on during the autobaud process, etc.
LED activity indicating functions:
Red – Shows device has power
Yellow – Shows device is transmitting data
Green – Shows device is receiving data
4
Install Click Supervisor
Click Supervisor will be used to configure the Click 301. Follow these steps to install it:
1 Download the setup file from www.wavetronix.com (under Support).
2 Double-click on the file to run the setup wizard. Follow the steps to install.
5
Make a connection
1 Make sure there is a connection between the Click 301 and the computer that
Click Supervisor is on. This can be through the DB-9 connector on the module or
through another device also on the T-bus; for example, the Click 421 can commu-
nicate with the computer through Bluetooth®.
2 Run Click Supervisor and select Communication. This screen lets you pick the
type of connection you want to make, serial or IP. The Click 301 must be config-
ured using serial communication.
3 Click Settings to make any necessary changes to the settings, such as the port or the baud
rate. Click OK to return to the Communication screen, then click Connect. Keep the Click ID set to 0.
4 In the next screen, Click Supervisor will display all the devices it discovers. When the Click 301 ap-
pears, select it and click Select. Click Supervisor will connect to the device.