beautypg.com

Component & system wiring 46, Minilink polling d evice commlink t erminals, 24 v a c class 2 t ransformer – WattMaster VAV User Manual

Page 46: Philips

background image

Component & System Wiring

46

Notes:

1.)

All

W

iring

T

o

Be

In

Accordance

With

Local

And

N

ational

Electrical

C

odes

And

S

pecifications.

2.)

All

C

ommunication

Wiring

T

o

Be

2

C

onductor

T

w

isted

P

air

With

Shield.

Use

B

elden

#82760

Or

Equivalent.

Component

W

iring

D

iagram

03/24/04

V

A

V

-MiniLinkPolDevW

r1A.CDR

MiniLink

Polling

D

evice

1o

f1

MiniLink

Polling

D

evice

CommLink

T

erminals

Only

First

MiniLink

PD

T

o

Be

Connected

T

o

CommLink,

Otherwise

Connect

MiniLink

PD

T

o

Network

T

erminals

Of

Previous

Or

Next

MiniLink

PD

On

Loop

24

V

A

C

Class

2

T

ransformer

Rated

For

6

V

A

Load

Minimum

Not

Used

T

o

WMV

A

V

Controller

T

erminals

MiniLink

P

D

Network

T

erminals

Connect

MiniLink

PD

T

o

Network

T

erminals

Of

Previous

Or

Next

MiniLink

PD

On

Loop.

EPROM

U3

U5

RAM

CX2

1

U2

R1

C3

U4

CX3

CX4

YS101818P552

PROCESSORPBOARD

CX5

C1

U1

R2

CX1

CX6

WDOG

U6

PHILIPS

D1

P1

X1

C2

C4

0-10V

4-20mA

THERM

R27

R31

D4

GND

GND

24VAC

24VAC

TB1

D5

C1

1

U12

LED

2

POWER

V1

R25

R26

C7

CX15

CX13

PROC.

DRIVER

LOOP

DRIVER

LOCAL

LOOP

GND

AIN2

AIN1

+5V

TB2

P4

OFF=0-5V

AIN2

AIN1

0-10V

4-20mA

THERM

TB3

U15

LD5

LD6

U13

C8

LED

1

RV

1

R4

VREF

CX2

U1

1

YS101900PMINILINK

POLLING

DEVICE

REV

.

1

OFF

1

2

4

8

16

32

CX14

NETWORK

DRIVER

RN3

SHLD

SHLD

SHLD

SHLD

T

T

G

T

T

T

TB4

R

R

485

LOOP

R

R

R

U14

NETWORK

LOOP

P5

ADD

P3

R24

LD4

C9

U10

RN2

SW1

R30

X2

R29

R28

C10

U6

CX6

CX1

U7

U1

X1

C3

C1

R3

CX7

Line

V

olt

age

16

32

8

4

2

1

Address

Switch

Shown

Is

Set

For

Address

1

Address

Switch

Shown

Is

Set

For

A

ddress

13

Controller

Address

Switch

This

Switch

Should

Be

In

The

OFF

Position

As

Shown

Note:

The

Power

T

o

The

MiniLink

PD

Must

Be

Removed

A

nd

Reconnected

Af

ter

Changing

The

Address

Switch

Settings

In

Order

For

Any

C

hanges

T

o

T

ake

Ef

fect.

Caution

Disconnect

All

Communication

Loop

Wiring

F

rom

The

MiniLink

PD

Before

Removing

Power

From

The

MiniLink

PD.

Reconnect

Power

And

Then

Reconnect

Communication

Loop

Wiring.

ADD

ADD

ADD

The

Address

For

Each

MiniLink

PD

Must

Be

Unique

T

o

The

Other

MiniLink

PDs

On

The

Local

Loop

And

B

e

Between

1

and

60

FILENAME

DA

TE:

B.

Crews

DESCRIPTION:

P

AGE

DRA

WN

BY

:

JOB

NAME

Communication

Wiring

T

o

Be

Wired

T

to

T

,

SHLD

(G)

to

SHLD

(G)

&

R

to

R

3.)

All

C

ommunication

W

iring

T

o

Be

2

C

onductor

T

w

isted

Pair

W

ith

Shield.

Use

Belden

#82760

Or

Equivalent.

MiniLink Polling Device Wiring Using Wire Terminals